Methods to reduce the energy consumption of sewage treatment Roots blower:
1. Choose a reasonable installation location, reduce the elbow, so that the outlet is facing the pool.
2. Shorten the pipeline.
3. Expand the diameter of the outlet pipe.
4. In the case that the inlet water can be kept clean, the filter can be removed.
5. Adjust the axial clearance to prevent improper impeller mouth ring and axial clearance, and adjust according to the pump's factory instructions when in use.
6. Remove the pipe blockage in time. Remove the foreign matter left inside the inlet pipe, impeller or guide shell flow channel
7. Prevent the pump from entering the air. If the water pump enters air, the water output will be reduced, and it is necessary to check and maintain each sealing part.